ABB · Industrial

IRB 1300 · IRB 1300-12/1.4 · OmniCore · standard IP40

Official mechanical variant with standard protection; controller supply, optional equipment and procurement availability require separate verification. Source revision X.

Baseline specifications checked

Availability awaiting verification · Checked 2026-11-22

Application classification

Industrial · Articulated arm · Profissional

Historical manufacturer brochure dated 2024-08-23. Current orderability and optional controller compatibility require confirmation.

    Product application evidence

    Detailed parameters

    22 / 32 parameter fields backed by recorded evidence

    29 / 32 fields checked within the recorded source scope

    This is a documentation checklist, not a performance score. Missing values are not zero, and support is not implied.

    Physical specifications 11 / 16
    Physical specifications · IRB 1300-12/1.4 · OmniCore · standard IP40
    ParameterValue and conditionsSource and verification
    Overall dimensionsNot yet verifiedNo sourced value recorded for this edition.
    Weight

    79 kg
    Manipulator only; additional options, tools and other fitted equipment are excluded.

    3HAC070393-001 Rev X · p. 23
    Official statement · 2026-11-22
    Document date 2026-09-17

    Degrees of freedom

    6
    Six axes are explicitly identified by the source motion/performance tables.

    3HAC070393-001 Rev X · p. 76
    Official statement · 2026-11-22
    Document date 2026-09-17

    Payload

    12 kg
    Nominal handling capacity for this exact mechanical variant. Optional tool loads and load diagrams must be respected.

    3HAC070393-001 Rev X · p. 118
    Official statement · 2026-11-22
    Document date 2026-09-17

    Reach

    1400 mm
    Manufacturer-declared reach for the named variant; reference geometry follows the source.

    3HAC070393-001 Rev X · p. 118
    Official statement · 2026-11-22
    Document date 2026-09-17

    Repeatability

    0.04 mm
    Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

    3HAC070393-001 Rev X · p. 76
    Official statement · 2026-11-22
    Document date 2026-09-17

    Path repeatability

    0.08 mm
    Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

    3HAC070393-001 Rev X · p. 76
    Official statement · 2026-11-22
    Document date 2026-09-17

    Accuracy and measurement conditions

    0.03 mm
    Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions. AP uses the source definition relative to a taught/programmed point; not an unconditional absolute accuracy guarantee.

    3HAC070393-001 Rev X · p. 76
    Official statement · 2026-11-22
    Document date 2026-09-17

    Path accuracy

    1.32 mm
    Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

    3HAC070393-001 Rev X · p. 76
    Official statement · 2026-11-22
    Document date 2026-09-17

    Pose stabilization time

    0.52 s
    Within 0.1 mm of position. Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

    3HAC070393-001 Rev X · p. 76
    Official statement · 2026-11-22
    Document date 2026-09-17

    SpeedNot found in reviewed sources

    No configuration-specific maximum TCP speed has been verified in the reviewed mechanical tables. ISO test velocity and maximum joint speeds are not substituted for maximum TCP speed.
    3HAC070393-001 Rev X · motion/performance sections · 2026-11-22

    Maximum joint speeds

    A1 280; A2 180; A3 250; A4 500; A5 415; A6 720 deg/s
    Maximum axis speeds, not maximum TCP or collaborative-safe speed. Supply and option conditions from the source apply.

    3HAC070393-001 Rev X · p. 77
    Official statement · 2026-11-22
    Document date 2026-09-17

    Mounting and footprint

    Floor; wall; suspended; any documented installation angle
    Mounting orientation must be configured correctly in controller parameters.

    3HAC070393-001 Rev X · p. 23
    Official statement · 2026-11-22
    Document date 2026-09-17

    Joint ranges and speedsNot yet verifiedNo sourced value recorded for this edition.
    Force sensing and controlRequires additional official documentation

    This mechanical product specification does not establish the full force requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
    3HAC070393-001 Rev X · scope and referenced documents · 2026-11-22

    End-effector and tool interfaceRequires additional official documentation

    This mechanical product specification does not establish the full tool requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
    3HAC070393-001 Rev X · scope and referenced documents · 2026-11-22

    Power and operating environment 6 / 6
    Power and operating environment · IRB 1300-12/1.4 · OmniCore · standard IP40
    ParameterValue and conditionsSource and verification
    Power supply and consumption

    0.47 kW
    ISO cube cycle at maximum rated load and maximum velocity. Not a mains-rating or whole-cell power requirement. Calibration-position consumption (brakes engaged / disengaged): 0.08 / 0.19 kW.

    3HAC070393-001 Rev X · p. 27
    Official statement · 2026-11-22
    Document date 2026-09-17

    IP rating

    IP40
    Standard protection package only; optional protection packages are recorded separately.

    3HAC070393-001 Rev X · p. 26
    Official statement · 2026-11-22
    Document date 2026-09-17

    Optional protection packages

    Optional IP67; Foundry Plus 2; Clean Room ISO 4
    These are selectable options and are not asserted to be included or freely combinable.

    3HAC070393-001 Rev X · p. 118
    Official statement · 2026-11-22
    Document date 2026-09-17

    Operating temperature

    5 to 45 degC
    Operating ambient; warm-up is recommended below 10 degC. Check the source for option-dependent restrictions.

    3HAC070393-001 Rev X · p. 26
    Official statement · 2026-11-22
    Document date 2026-09-17

    Operating humidity

    <=95% at constant temperature RH
    No condensation; source option-specific conditions remain applicable.

    3HAC070393-001 Rev X · p. 26
    Official statement · 2026-11-22
    Document date 2026-09-17

    Noise and measurement conditions

    <70 dB(A) Leq
    Published sound pressure outside working space; actual path, load, cycle, installation and environment affect noise.

    3HAC070393-001 Rev X · p. 27
    Official statement · 2026-11-22
    Document date 2026-09-17

    Perception, software and integration 3 / 7
    Perception, software and integration · IRB 1300-12/1.4 · OmniCore · standard IP40
    ParameterValue and conditionsSource and verification
    I/O and communication interfacesNot yet verifiedNo sourced value recorded for this edition.
    Controller configuration

    OmniCore
    Controller family in the source. This entry is a mechanical/base-protection variant, not a verified complete supplied package.

    3HAC070393-001 Rev X · p. 3
    Official statement · 2026-11-22
    Document date 2026-09-17

    Software and operating system

    RobotWare on OmniCore
    Software release and licensed options must match the selected controller; no SDK/ROS compatibility is inferred.

    3HAC070393-001 Rev X · p. 14
    Official statement · 2026-11-22
    Document date 2026-09-17

    SDKRequires additional official documentation

    This mechanical product specification does not establish the full sdk requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
    3HAC070393-001 Rev X · scope and referenced documents · 2026-11-22

    ROS supportRequires additional official documentation

    This mechanical product specification does not establish the full ros requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
    3HAC070393-001 Rev X · scope and referenced documents · 2026-11-22

    Software license and accessRequires additional official documentation

    This mechanical product specification does not establish the full license requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
    3HAC070393-001 Rev X · scope and referenced documents · 2026-11-22

    Hardware requirements

    OmniCore controller family required
    Exact controller model, power supply, tooling and software/options must be confirmed for the supplied system.

    3HAC070393-001 Rev X · p. 3
    Official statement · 2026-11-22
    Document date 2026-09-17

    Safety, application and support 2 / 3
    Safety, application and support · IRB 1300-12/1.4 · OmniCore · standard IP40
    ParameterValue and conditionsSource and verification
    Documented intended use

    Material handling, machine tending, polishing, assembly and testing.
    Manufacturer intended-use statement; this is not a validated site deployment.

    3HAC070393-001 Rev X · p. 11
    Official statement · 2026-11-22
    Document date 2026-09-17

    Safety functions and standardsRequires additional official documentation

    This mechanical product specification does not establish the full safety requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
    3HAC070393-001 Rev X · scope and referenced documents · 2026-11-22

    Warranty and support

    12 months after customer delivery or 18 months after factory shipment, whichever occurs first
    Standard option 438-1; manufacturer terms apply. See source for maintenance, exclusions and alternative warranty options.

    3HAC070393-001 Rev X · p. 120
    Official statement · 2026-11-22
    Document date 2026-09-17

    Price records

    Request a configuration-specific quotation

    No verified price recorded. Request a configuration-specific quotation.

    Suggest a correction or claim manufacturer ownership