ABB · Industrial

GoFa CRB 15000 · CRB 15000-12/1.27 · OmniCore · standard IP67

Official mechanical variant with standard protection; controller supply, optional equipment and procurement availability require separate verification. Source revision Y.

Baseline specifications checked

Availability awaiting verification · Checked 2026-11-22

Application classification

Industrial · Articulated arm · Professioneel

Industrial articulated manipulator configuration documented by the manufacturer; application integration and safety require their own assessment.

  • Industrial · handling and machine tending · Handling · IFR
Product application evidence

Detailed parameters

23 / 31 parameter fields backed by recorded evidence

29 / 31 fields checked within the recorded source scope

This is a documentation checklist, not a performance score. Missing values are not zero, and support is not implied.

Physical specifications 14 / 17
Physical specifications · CRB 15000-12/1.27 · OmniCore · standard IP67
ParameterValue and conditionsSource and verification
Overall dimensionsNot yet verifiedNo sourced value recorded for this edition.
Weight

48 kg
Manipulator only; additional options, tools and other fitted equipment are excluded.

3HAC077390-001 Rev Y · p. 18
Official statement · 2026-11-22
Document date 2026-09-18

Degrees of freedom

6
Six axes are explicitly identified by the source motion/performance tables.

3HAC077390-001 Rev Y · p. 70
Official statement · 2026-11-22
Document date 2026-09-18

Payload

12 kg
Nominal handling capacity for this exact mechanical variant. Optional tool loads and load diagrams must be respected.

3HAC077390-001 Rev Y · p. 104
Official statement · 2026-11-22
Document date 2026-09-18

Reach

1270 mm
Wrist reference explicitly defined in this source.

3HAC077390-001 Rev Y · p. 104
Official statement · 2026-11-22
Document date 2026-09-18

Flange reach

1380 mm
Tool-flange reference; separate from the wrist reach in the same table.

3HAC077390-001 Rev Y · p. 104
Official statement · 2026-11-22
Document date 2026-09-18

Repeatability

0.02 mm
Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

3HAC077390-001 Rev Y · p. 70
Official statement · 2026-11-22
Document date 2026-09-18

Path repeatability

0.058 mm
Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

3HAC077390-001 Rev Y · p. 70
Official statement · 2026-11-22
Document date 2026-09-18

Accuracy and measurement conditions

0.02 mm
Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions. AP uses the source definition relative to a taught/programmed point; not an unconditional absolute accuracy guarantee.

3HAC077390-001 Rev Y · p. 70
Official statement · 2026-11-22
Document date 2026-09-18

Path accuracy

2.377 mm
Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

3HAC077390-001 Rev Y · p. 70
Official statement · 2026-11-22
Document date 2026-09-18

Pose stabilization time

0.887 s
Within 0.1 mm of position. Manufacturer ISO 9283 test: rated load and offset, inclined plane, all six axes moving; individual results depend on pose, approach and load conditions.

3HAC077390-001 Rev Y · p. 70
Official statement · 2026-11-22
Document date 2026-09-18

SpeedNot found in reviewed sources

No configuration-specific maximum TCP speed has been verified in the reviewed mechanical tables. ISO test velocity and maximum joint speeds are not substituted for maximum TCP speed.
3HAC077390-001 Rev Y · motion/performance sections · 2026-11-22

Maximum joint speeds

A1 120; A2 120; A3 125; A4 200; A5 200; A6 200 deg/s
Maximum axis speeds, not maximum TCP or collaborative-safe speed. Supply and option conditions from the source apply.

3HAC077390-001 Rev Y · p. 71
Official statement · 2026-11-22
Document date 2026-09-18

Mounting and footprint

Floor (0 deg); wall (documented angles); inverted (180 deg)
Mounting orientation must be configured correctly in controller parameters.

3HAC077390-001 Rev Y · p. 18
Official statement · 2026-11-22
Document date 2026-09-18

Joint ranges and speeds

A1 +/-270; A2 +/-180; A3 -225/+85; A4 +/-180; A5 +/-180; A6 +/-270 deg
Default software working ranges only; mounting, payload, coupled axes and optional extensions impose further restrictions. Use the complete source before integration.

3HAC077390-001 Rev Y · p. 69
Official statement · 2026-11-22
Document date 2026-09-18

Force sensing and control

Torque sensors on all 6 joints; power and force limiting functions
Controller safety functions and all remaining application hazards must be verified before operation.

3HAC077390-001 Rev Y · p. 12
Official statement · 2026-11-22
Document date 2026-09-18

End-effector and tool interfaceRequires additional official documentation

This mechanical product specification does not establish the full tool requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
3HAC077390-001 Rev Y · scope and referenced documents · 2026-11-22

Power and operating environment 4 / 4
Power and operating environment · CRB 15000-12/1.27 · OmniCore · standard IP67
ParameterValue and conditionsSource and verification
Power supply and consumption

0.25 kW
ISO cube cycle at maximum rated load and maximum velocity. Not a mains-rating or whole-cell power requirement. Calibration-position consumption (brakes engaged / disengaged): 0.14 / 0.10 kW.

3HAC077390-001 Rev Y · p. 23
Official statement · 2026-11-22
Document date 2026-09-18

IP rating

IP67
Standard protection package only; optional protection packages are recorded separately.

3HAC077390-001 Rev Y · p. 21
Official statement · 2026-11-22
Document date 2026-09-18

Operating temperature

0 or 5 to 45 degC
0 degC requires RobotWare 8.2 or later; otherwise minimum 5 degC. GoFa 5 maximum 40 degC; GoFa 10/12 maximum 45 degC.

3HAC077390-001 Rev Y · p. 21
Official statement · 2026-11-22
Document date 2026-09-18

Operating humidity

<75%; limited periods under one month <95% RH
No condensation; source option-specific conditions remain applicable.

3HAC077390-001 Rev Y · p. 21
Official statement · 2026-11-22
Document date 2026-09-18

Perception, software and integration 3 / 7
Perception, software and integration · CRB 15000-12/1.27 · OmniCore · standard IP67
ParameterValue and conditionsSource and verification
I/O and communication interfacesNot yet verifiedNo sourced value recorded for this edition.
Controller configuration

OmniCore C30 only
The current specification explicitly restricts this robot to OmniCore C30; software release and delivery contents require confirmation.

3HAC077390-001 Rev Y · p. 12
Official statement · 2026-11-22
Document date 2026-09-18

Software and operating system

RobotWare on OmniCore
Software release and licensed options must match the selected controller; no SDK/ROS compatibility is inferred.

3HAC077390-001 Rev Y · p. 12
Official statement · 2026-11-22
Document date 2026-09-18

SDKRequires additional official documentation

This mechanical product specification does not establish the full sdk requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
3HAC077390-001 Rev Y · scope and referenced documents · 2026-11-22

ROS supportRequires additional official documentation

This mechanical product specification does not establish the full ros requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
3HAC077390-001 Rev Y · scope and referenced documents · 2026-11-22

Software license and accessRequires additional official documentation

This mechanical product specification does not establish the full license requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
3HAC077390-001 Rev Y · scope and referenced documents · 2026-11-22

Hardware requirements

OmniCore controller family required
Exact controller model, power supply, tooling and software/options must be confirmed for the supplied system.

3HAC077390-001 Rev Y · p. 3
Official statement · 2026-11-22
Document date 2026-09-18

Safety, application and support 2 / 3
Safety, application and support · CRB 15000-12/1.27 · OmniCore · standard IP67
ParameterValue and conditionsSource and verification
Documented intended use

Industrial applications; other uses require separate standards verification and application risk assessment.
Manufacturer intended-use statement; this is not a validated site deployment.

3HAC077390-001 Rev Y · p. 11
Official statement · 2026-11-22
Document date 2026-09-18

Safety functions and standardsRequires additional official documentation

This mechanical product specification does not establish the full safety requirement for the configured system. Additional controller, software, safety or application documents must be reviewed.
3HAC077390-001 Rev Y · scope and referenced documents · 2026-11-22

Warranty and support

12 months after customer delivery or 18 months after factory shipment, whichever occurs first
Standard option 438-1; manufacturer terms apply. See source for maintenance, exclusions and alternative warranty options.

3HAC077390-001 Rev Y · p. 104
Official statement · 2026-11-22
Document date 2026-09-18

Price records

Request a configuration-specific quotation

No verified price recorded. Request a configuration-specific quotation.

Suggest a correction or claim manufacturer ownership